ANALOG CONTROL


               Connection- alt.  If the wire shield needs to be grounded at the
               shielding      enable voltage source, then the shield cannot also
                              be grounded at the negative (-) terminal output of
                              the PHU power supply. This would short the
                              output.
























                                Pin5 → VREF
                                Pin4 → EXT-V/R IN_R CONT
                                Pin6 or Pin10 or Pin24 or Pin25 → Analog GND
                                Pin14 → Enable (+)
                                Pin15 or Pin16 or Pin23 → Enable (-)
                                Wire shield → Enable voltage ground (GND)
                                Variable resistor: 10 kΩ to 1 MΩ

               Panel operation   1.  Connect the external voltage according to the
                                 connection diagrams above.